But a 30 inch by 30 level floor area is required by code at the front service side of the water heater per m1305 1 2 of the international residential code irc and residential edition of the florida building code fbc.
Tankless gas water heater clearance.
The rheem eco200xln3 1 outdoor natural gas tankless water the rheem eco200xln3 1 outdoor natural gas tankless water heater can provide up to 9 5 gpm at a 35 temperature rise.
Direct vent units pull in air from outside the house so they have two vents for intake and exhaust.
Tankless water heaters should not be installed near dryer vents or intake air vents.
Cpc 508 4 required access clearances to combustibles and vent termination location per manufacturer s instructions.
Power vent units use indoor air for combustion and simply vent the exhaust to the outside.
In short installation isn t usually as simple as just plugging and playing.
Not installed in attic or other spaces where damage may result from a leaking water heater without an approved safe pan beneath the water heater with a minimum inch drain to an approved readily visible location.
Tankless water heater vent clearances if the unit is vented to the outside then it needs 12 inches of clearance from a door or window.
Get free shipping on qualified special buys clearance tankless gas water heaters or buy online pick up in store today in the plumbing department.
A tankless water heater requires a 4 foot clearance from the side or below a door or window that opens unless the unit is directly vented to the outside.
The clearance at the sides back and above a gas water heater are specified by the manufactured in the installation manual and they typically vary from zero to just a few inches.
The 199 900 btu natural gas tankless water heater is designed to supply continuous hot water for up to 3 bathrooms at the same time.
Rinnai super high efficiency 6 5 gpm residential 130 000 btu natural gas interior tankless water heater model rucs65in 795 42 795 42 unit.
Rinnai super high efficiency plus 9 8 gpm indoor natural gas tankless water heater.
If the water heater is installed above the.
Tankless water heaters can be vented in two ways.
If the window does not open the tankless water heater clearance from a window requires a 12 inch setback.
Sunday june 17 2018 an outdoor gas tankless water heater should not be located within an area extending twelve inches to the side and one foot above or below any door or the operable area of a window that can be opened per ansi a21 10 3.